FOTOTERAPIA EN RECIEN NACIDOS PDF

Development of an eye protector for phototherapy on newborns: a technology. Hyperbilirubinemia results from the predisposition of newborns to produce bilirubin and their ability to excrete it. The treatment applied is phototherapy; however, one of its complications is degeneration of the retina by exposure to light, making it essential to provide proper eye protection. The objective of this study is to describe the development of an invention utility model patented for eye protection in newborn phototherapy.

Author:Kagakora Zulkikus
Country:Central African Republic
Language:English (Spanish)
Genre:History
Published (Last):26 October 2007
Pages:320
PDF File Size:2.50 Mb
ePub File Size:10.37 Mb
ISBN:955-5-49136-342-8
Downloads:10884
Price:Free* [*Free Regsitration Required]
Uploader:Kagis



I RN, e-mail: annelaura1 hotmail. The effectiveness of neonatal hyperbilirubinaemia treatment depends directly on the amount of energy emitted by light irradiance. The measurement of irradiance was carried out with a radiometer. We observed that The conclusion is that the majority of phototherapy devices are emitting the minimum required irradiance for neonatal jaundice treatment. Descriptors: jaundice; phototherapy; infant, newborn; light; radiation measurement.

Hyperbilirubinaemia is the most frequent pathology in the neonatal period. Currently, the most used therapies to control serum-unconjugated hyperbilirubinaemia in the neonatal period include phototherapy and exchange transfusions 2. Phototherapy is the most used specific therapy because it is a non-invasive method of high impact that diminishes levels of plasmatic bilirubin, regardless of neonatal maturity, presence or not of hemolysis or degree of cutaneous pigmentation 3.

These treatment action mechanisms mainly include configurational and structural photoisomerization of the bilirubin molecule with photoisomers compounds, which are excreted through biliary and urinary routes without the need for hepatic conjugation 2.

Historically, exchange transfusion was the most used therapy, probably due to inefficient phototherapy, which increases the risk of morbimortality that varied according to the services and neonatologists' experience 4. The efficacy of neonatal hyperbilirubinaemia treatment depends directly on the amount of energy emitted by light irradiance 5.

Therefore, controlling phototherapy equipment in neonatal units is needed. There is a minimum level of irradiance for each type of equipment. The bilirrubin molecule absorbs visible light ranging from and nm, with peaks around nm 5. Irradiance is considered the amount of energy emitted on a certain surface, by its unit of area 6. Since phototherapy was discovered, 40 years ago, not only indications for its use have changed considerably as new and more efficient models have been introduced in the market 7.

Assuming that there is variability in the type of device and light bulb used, the characteristics of each type of device have to be known. The conventional or common phototherapy uses from six to eight white fluorescent bulbs day light 6 ; some devices already have interspersed blue bulbs, at least two. These devices present an irradiance two to three times higher than that observed in devices with white bulbs 6,8. This kind of bulb is not made in Brazil and its importation is hindered by administrative bureaucracy and high costs 9.

It consists of a light source with halogen light bulbs, preferably used in premature infants due to the size of the light source 5. It has irradiance above that emitted by conventional devices. Phototherapy efficacy depends directly on the amount of energy emitted in the wave range correspondent to the absorption of light by the bilirubin molecule, on the wave length color and intensity of irradiance energy of the used source 1. The non-observance of technical criteria appropriate for the use of this technology can harm the efficacy of the therapy and the quality of treatment delivered to newborns with jaundice 2.

The mere act of exposing the newborn to light when phototherapy is initiated does not necessarily imply the delivery of appropriate treatment 7. Treating neonatal jaundice also means monitoring the bulbs used in the phototherapy devices, aiming to always keep appropriate irradiance. Knowledge about how light acts and the type of bulb used should be constantly monitored for its application in neonatal hyperbilirubinaemia treatment.

The device whose irradiance is not monitored can aggravate the newborns' clinical condition and consequently prolong hospitalization. Routine irradiance measurement of these devices would ensure the efficacy of phototherapy and therefore reduce newborns' hospitalization, diminishing the risk of hospital-acquired infection.

The implementation of a measurement routine can also favor the identification of the need to change or maintain the device, optimizing the quality of care delivery. This is a cross-sectional and descriptive study with a qualitative approach. This study was not submitted to any Research Ethics Committee because it does not involve human subjects. Among the seven maternities chosen, only one did not authorize the study. The remainder signed the document authorizing the study.

The hospitals were clarified about the study objectives and the way data would be collected. Anonymity and access to data were ensured, and it was guaranteed that data would only be used for scientific purposes.

Equipments in use in the maternities were included in the study and all those in maintenance were excluded. It is a simple device, operated with a 9-volt battery. The average therapy used was in accordance to each evaluated device. This study was guided by Fernando Facchini's Proposal of Standardization, which for the evaluation of conventional devices, recommends the measurement of irradiance on the surface of the mat with a sheet of cardboard measuring 34x60cm fixed on the surface. An area of 42x34cm was marked in the center of this sheet, which corresponds to the projection of the phototherapy device, since it is used in transverse position in relation to the incubator.

This area was divided in nine rectangles of equal areas and, in the center of each, a part was cut in the form of the radiometer used for the readings. The arithmetic average of these nine portions is considered the average spectral irradiance, which the newborn under treatment is subject to 6. In each of these areas, four diametrically opposed points were marked so as to serve as the measurement site of irradiance, which according to the manufacturer itself, reduces considerably from the center to the periphery.

Arithmetic averages of these four points, once weighted with their respective areas and summed, provided the spectral average of the energy beam therapy 6. On the other hand, there was no standardization for the Bilitron devices published in the field. Thus, the study was guided by the manufacture's guidelines according to the used bulb. Reading was done around cm in the central region of the super LEDs - central point. Data were stored in an electronic spreadsheet and descriptive analysis was carried out using the Statistical Package for the Social Sciences SPSS version The 36 devices were analyzed in terms of their spectral irradiance, type of device, used bulb and quantity of bulbs by device, in addition to the existence of radiometers in the six studied hospitals.

The device has irradiance above that emitted by the conventional type, but its distribution is irregular, which diminishes its efficacy in relation to the irradiance value. In relation to the type of used bulbs, there was a predominance of tungsten halogen bulbs, characterized by high-emitted irradiance, cooled by a system of forced air circulation to dissipate some of the produced heat.

They have a filtering system of undesirable radiations, such as those of the infrared band in phototherapy 6. The presence of radiometers in the hospitals revealed concern with monitoring the irradiance emitted by these devices and half of the studied hospitals had devices to measure irradiance. Comparing the irradiances in limit parameters of emitted dosage, we verified that Table 4.

Adequate bulbs, according to the type of device, directly influence the efficacy of emitted irradiance. Of the studied devices, 8. In terms of adequate irradiance by type of device, the study showed that, of the 36 studied devices, Table 5. Phototherapy to treat jaundice has been the main choice for more than 30 years and has been efficient and safe to diminish indices of bilirubin, whose rate of decline is proportional to the emitted light, indicating that, the higher the intensity of phototherapy irradiance, the higher its efficacy 4.

The dosage of phototherapy largely determines how fast bilirubin will return to its normal levels. When intensive phototherapy is used, one can expect it will decrease between 0. Therefore, the higher the irradiance emitted by the phototherapy device, the better and faster the therapy will be 4.

The need to monitor the measurement of the phototherapy devices' irradiance has been described for some time in international literature. In Brazilian literature, some studies address the analysis of irradiance of phototherapy devices in hospitals. The majority of studies are linked to higher education institutions. These studies focus on factors that interfere in treatment efficacy, including exposure of the newborn to light, distance of the newborn from the light, change of decubitus, eye protection and hydration of babies, while the measurement of the devices' irradiance is carried out in a single central point, with distance found above the newborn, directly measuring the irradiance, excluding peripheral exposed areas.

These studies also emphasize the need to use blue bulbs to increase the potency of the irradiance, with prevalence of white and blue bulbs. However, the efficacy of the phototherapy does not depend only on color, but also on the irradiance of light This study evaluated the irradiance of the device in satisfactory conditions in relation to the distance between the light and the cradle and incubators.

The majority of phototherapy devices presented incorrect distances in relation to the newborn and these distances were corrected before starting the measurement so as to avoid that the distance standardization error interfered in the irradiance value. We considered that the irradiance emitted by the device could even be adequate, but that incorrect distances could be inefficaciously dissipating the light.

We also measured all points reflected by light on the newborn, establishing a spectral average according to Facchini's proposal 6. Irradiance has to be measured in multiple sites below the lighted area, by unit, and the average measurements were calculated because the measurement at the center of the light source can be twice the measurement at the periphery 4.

These strategies allowed us to obtain more reliable data. An analysis about the irradiance of phototherapy devices was carried out in in hospitals in Curitiba, PR, Brazil and the conclusion was that almost half of the devices used in the treatment of neonatal jaundice were inefficacious 9.

Another study was carried out in in Brasilia, also addressing the irradiance of phototherapy in a teaching hospital, which concluded that the facility needed to arrange for the devices' maintenance and buy new phototherapy equipment However, treatment efficacy does not depend only on spectral irradiance, but also on the spectrum of emitted light, spectral power in relation to the exposed surface and on the cause of the jaundice 4.

Adequate irradiance of phototherapy devices is only one of the several criteria required for treatment success. In addition, positioning the newborn at the ideal distance for each type of device, exposing the largest possible body surface and the time newborns are exposed to light also interfere in therapy success.

Efficacy of therapy should be assessed in all cases and the level of irradiance should be indicated and recorded. It should also be measured in multiple sites below the lighted area by unit of measurement, because irradiance diminishes as one gets away from the central area 4.

There is a large number of devices emitting the minimum recommended irradiance value to promote the reduction of serum bilirubin levels. The maintenance of parameters of irradiance and consequent interference of this maintenance in the efficacy of newborns treatment depends directly on a qualified nursing team. Efficient phototherapy diminishes the newborns' time of hospitalization and unnecessary exposure to phototherapy treatment for a prolonged time.

This study shows that However, it is imperative that professionals make possible the inclusion of measurement and maintenance routine of these devices, favoring a higher emission of irradiance. The expression "not everything that illuminates, treats" 14 translates the importance of checking the irradiance of these devices as well as the maintenance of these bulbs, creating a routine to change and calibrate the radiometer.

Almeida MFB. Jornal de Pediatria ; 80 4 Acta Paul Enferm ; 16 2 Segre AMC. In: Bastos F, organizador. Facchini F. J Pediatria ; 77 2 Scientia Medica ; 15 2 Klielmann R, Nohama P.

DURGA DEVI ASHTOTRA SHATANAMAVALI IN TELUGU PDF

RECIEN. Revista Científica de Enfermería

Rev Cient Enferm. Nuber Cientif [Internet]. Mex Pediatr [Internet]. The effects of Field massage technique on bilirubin level and the number of defecations in preterm infants. Evid Based Care J. Effects of baby massage on neonatal jaundice in healthy Iranian infants: A pilot study. Infant Behav Dev.

ALEKSANDRA POTER PAZI STA ZELIS PDF

Cuando su bebé está en la unidad de cuidados intensivos neonatales (UCIN)

.

C373 TRANSISTOR PDF

Síndrome del bebé bronceado, una complicación impredecible de la fototerapia

.

PANFLETO CONTRA LA ESTUPIDEZ CONTEMPORANEA PDF

Ictericia en recién nacidos (hiperbilirrubinemia)

.

Related Articles